Full ceiling intake filters provide evenly balanced airflow throughout the booth cabin. Light fixtures are strategically located in the cabin walls to provide optimum, color corrected illumination. All stages of the paint process are operated and monitored through the Speed Convection Control System™.
Click Here to download the Premier Spray Booth brochure
TIDDP | 24′ | 27′ | 30′ |
Interior Dimensions | 24′ | 27’6″ | 29’9″ |
Exterior Dimensions | 24’5″ | 27’11″ | 30’2″ |
Lighting Output | 4-Tube T8 Bulbs | ||
Amount of Fixtures | 17 | 21 | 21 |
Amount of Bulbs | 68 | 84 | 84 |
Cabin Wall Design | Double Wall Insulated | ||
Panel Orientation | Horizontal Wall Panels | ||
Mercury Heaters | |||
BTU (millions/hour) | 1.0 Standard – 1.5 Optional | ||
CFM | 14,000 | 15,200 | 18,200 |
Temperature Rise | 90 F° Spray / 180 F° Bake | ||
Pit Configuration 39″ W x 30″ D | Single Row Pit | ||
Pit Length | 20′ | 23′ | 26½’ |
Fan Configuration | |||
Intake Type | Dual Inlet Centrifugal | ||
Motor HP | 10 | 10 | 10 |
Exhaust Type | Tube Axial Fan | ||
Exhaust Size | 32″ | 32″ | 42″ |
Motor HP | 7½ | 7½ | 7½ |